User Guide FlatMesh Nano / NanoPlus / NanoMacro / NanoMacro(High-G Variant) FM3NT-10 FM3NT-30 FM3NT-50 FM3NT-50H 0.
Contents Worldwide Information 0.0.1 USA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.0.2 Canada . . . . . . . . . . . . . . . . . . . . . . . . . . ii ii iii 1 Overview 1.1 The FlatMesh System . . . . . . . . . . . . . . . . . . . . . . 1.2 FlatMesh Nano / NanoPlus / NanoMacro Nodes . . . . . . 1.2.1 Physical Specifications FM3NT-10 and FM3NT-30 1.2.2 Physical Specifications FM3NT-50 and FM3NT-50H 1.2.3 Internal Battery FM3NT-10 and FM3NT-30 . . . . 1.2.
Worldwide Information Warning Protection provided by the equipment may be impaired if used in a manner contrary to this user manual. This product must not be disposed of in the normal waste stream. It contains a battery pack and electronic components and so should be recycled appropriately. In accordance with the WEEE guidelines, customers in the European Union may return the product free of charge for recycling at the end of its life. Contact your supplier for details. 0.0.
WORLDWIDE INFORMATION 0.0.2 iii Canada This device contains a licence-exempt transmitter that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS-247. Operation is subject to the following two conditions: • This device may not cause interference. • This device must accept any interference, including interference that may cause undesired operation of the device. The safe distance for human exposure to electromagnetic field is 20cm.
Chapter 1 Overview 1.1 The FlatMesh System A FlatMesh network consists of a number of nodes connecting to one gateway device. In some situations multiple networks may be required on a single site, for example a site in which the number of nodes exceeds the number supported by a single Gateway, or a site where there are a set of separate measurement zones. A FlatMesh Node is a sensing unit with an integrated wireless mesh radio and battery.
CHAPTER 1. OVERVIEW 2 Note Readings can be scheduled anywhere between two seconds and twelve hours with a time increment of one second, but it should be noted that the repeatability of the measurements are poorer when used at reporting rates faster than 10 seconds. 1.2.
CHAPTER 1. OVERVIEW 3 1.2.3 Internal Battery FM3NT-10 and FM3NT-30 Model Battery Type Nominal Voltage Nominal Capacity Typical Battery Life FM3NT-10 FM3NT-30 Lithium Man- Lithium Thionyl ganese Dioxide, Chloride, nonnon-rechargeable rechargeable 3.0V 3.6V 1000mAh 4400mAh 10 months 4 years At 20 minute reporting intervals, including when acting as a relay node Consult with Senceive for your application 1.2.
CHAPTER 1. OVERVIEW 4 1.2.6 Tilt Sensor Specifications Resolution Repeatability Repeatability (High-G variant) Range 0.0001° (0.00175mm/m) ±0.0005° (0.0087mm/m) ±0.0025° (0.
Chapter 2 Installation The nodes will be delivered to you pre-configured. Simply affix the nodes to a structure within the range of the rest of the network. 2.1 Mounting There are several mounting options available, including those designed for: • clamping to a structure using straps • magnetic mounting • gluing to any surface • fitting to an M8 threaded socket • fixing to a FlatMesh tilt beam kit Ensure that the fixing is secure to ensure that tilt measurements are representative of the structure.
Chapter 3 Maintenance The product should not require any maintenance after installation. If the need to clean the product should arise, use only a damp cloth and mild detergent. Do not use any solvents as this may damage the enclosure. Warning Only service personnel authorised by the manufacturer may open the enclosure. No user serviceable parts are located inside.
Chapter 4 Support 4.1 Contact Information For assistance and support, contact your supplier or the manufacturer: Senceive Limited Phone: +44 (0) 207 731 8269 Email: support@senceive.com Web: http://www.senceive.
Appendix A Import / Export Restrictions The products described in this user manual contain and use encryption algorithms for data authentication and security. Some countries require registration of these technologies. It is the importer’s responsibility to comply with all local regulations. Contact Senceive for more information.