User's Guide

CHAPTER 1. OVERVIEW 2
1.2.1 FM3N-LDS-IX(H) Physical Specification
Dimensions 90 x 90 x 60 mm
Total Mass 0.6 kg (approx.)
Housing Material Die cast aluminium body
International
Protection Marking
IP68 (1m for 24 hours)
Mounting Options Horizontal magnetic / wall mount
Node Operating
Temperature Range
1)
-25°C to +70°C
Laser Operating
Temperature Range
2)
-10°C to +50°C
1. The node will participate in the FlatMesh network and provide tilt and onboard sensor
readings within this temperature range.
2. Laser displacement readings will only be available within this temperature range. The
laser will not activate outside of this range.
1.2.2 Internal Battery
Battery Type Lithium Thionyl Chloride, non-
rechargeable
Nominal Voltage 3.6V
Nominal Capacity 19000mAh
Typical Battery Life 8 years at 30 minute reporting inter-
vals, including when acting as a relay
node.
Consult with Senceive for your applica-
tion.
1.2.3 FlatMesh Radio Specifications
Communication Type Proprietary FlatMesh v3 Mesh Net-
working Protocols
IEEE 802.15.4 compliant
Frequency Band 2400 - 2485 MHz ISM Band
Maximum Transmit
Power
6.5dBm
(EN 300 328 v1.8.1)
Maximum Antenna
Gain
2.2dBi
Range Up to 300m depending on the environ-
ment and fitted antenna
Consult with Senceive for your applica-
tion
RF Module Senceive FM3Node