User Manual
Table Of Contents
- Contents
- 1 About This Getting Started Guide
- 2 Unpacking the ZoneFlex Access Point
- 3 Before You Begin
- 4 Configuring the Access Point
- Configuring for Management by ZoneDirector
- Configuring for Standalone Operation or for Management by FlexMaster
- What You Will Need
- Step 1: Prepare the Administrative Computer
- Step 2: Connect the Access Point to the Administrative Computer
- Step 3: Log Into the Access Point’s Web Interface
- Step 4: Configure the Wireless Settings
- Step 5: Disconnect the Access Point from the Administrative Computer
- Step 6: Restore the Administrative Computer’s Network Settings
- 5 Attaching the Mounting Brackets
- 6 Connecting to the Network
- 7 Verifying the Installation
- 8 Joining the Mounting Brackets
- 9 (Optional) Mounting and Connecting the External Antenna
- 10 What to Do Next
- 11 Professional Installation Instructions
37
Connecting to the Network
Step 2: Attach the Dynamic Bracket to the Access Point
Figure 24. Install the white P-clip clamp and the black rubber O-ring
9. (Optional) Connect a DC cable (not supplied with the Access Point) into the DC
terminal block.
WARNING: Do not connect the DC cable to the DC power source at this point. You will
connect it later after you finish mounting the Access Point.
a. Take out the DC terminal block from the small plastic bag that contains the bottom
cover of the Access Point.
b. Connect the ground wire to V- terminal. If you are looking at the terminal block with
the wiring terminal screws on top, the V- terminal is on the left side.
c. Connect the +12v DC wire to the V+ terminal. If you are looking at the terminal
block with the wiring terminal screws on top, the V+ terminal is on the right side.
Rubber
O-ring
P-clip Cable
Clamp