User's Manual

~61~
Technical Specifications
Electrical Specifications Base Station Portable Handset
Frequency 902-928 MHz 902-928 MHz
RF Output Power
Peak: 27 dBm
Average: 21 dBm
Peak: 26 dBm
Average: 20 dBm
Channel Spacing 101 kHz 101 kHz
Number of Channels 252 252
Modulation Differentially Encoded MSK Differentially Encoded MSK
Multiple Access Frequency Hopping TDD Frequency Hopping TDD
Frequency Hopping Rate 100 per second 100 per second
TDD Frame Length 10 ms 10 ms
Number of Slots/Frame 4 4
Receiver Sensitivity
<-111dBm (@ BER 10
-2
) <-111dBm (@ BER 10
-2
)
Antenna Gain 2 dBi Long: 2.5 dBi; Short: 1.5 dBi
Antenna Connector Reversed TNC Proprietary
Telephone Interface RJ11 x 2 NA
Channel Coding 8 kbps Convolutional + CRC 8 kbps Convolutional + CRC
Transmission Data Rate 85.333 kbps 85.333 kbps
Speech Coding 8 kbps G.729AB 8 kbps G.729AB
User Data Rate 64kbps duplex 64kbps duplex
Duplex Time Division Duplex (TDD) Time Division Duplex (TDD)
Number of System ID 65,536 65,536
Ring Signal 20-50 Hz, 30-90 Vrms NA
Flash Time 100-900 ms programmable
NA
Power Source AC/DC 5V/1A Adapter 3.7V/1100mAh Li-Ion Battery
550mA
Charger Current
NA
(550/850mA for desktop
charger)
Charge Time NA 3hours
Regulation Compliance
FCC Part 15, Part 68
Canada RSS-210, CS03
FCC Part 15, Part 68
Hearing Aid Compatible
Canada RSS-210, CS03
Operating Temperature 0 – 50 °C -10 – 60 °C
Storage Temperature
-40 – 70 °C -40 – 70 °C
Humidity 20 – 75 % 20 – 75 %
Notes:
1.
NA = Not Applicable.
2.
The manufacturer reserves the right to change designs and specifications without
notice.
~62~
FCC Part 68 Statement
This equipment complies with Part 68 of the FCC rules and the requirements
adopted by the ACTA. On the bottom of FreeStyl 2 base station is a label that
contains, among other information, a product identifier in the format US:
SNIW403BFS2. If requested, this number must be provided to the telephone
company.
Applicable connector jack Universal Service Order Codes (“USOC”) for the
Equipment is RJ11C.
A plug and jack used to connect this equipment to the premises wiring and
telephone network must comply with the applicable FCC Part 68 rules and
requirements adopted by the ACTA. A compliant telephone cord and modular
plug is provided with this product. It is designed to be connected to a compatible
modular jack that is also compliant. See installation instructions for details.
The REN is used to determine the number of devices that may be connected to a
telephone line. Excessive RENs on a telephone line may result in the devices not
ringing in response to an incoming call. In most but not all areas, the sum of RENs
should not exceed five (5.0). To be certain of the number of devices that may be
connected to a line, as determined by the total RENs, contact the local telephone
company. For products approved after July 23, 2001, the REN for this product is part
of the product identifier that has the format US: SNIW403BFS2. The digits
represented by 0.3 are the REN without a decimal point (e.g., 03 is a REN of 0.3).
If this FreeStyl 2 causes harm to the telephone network, the telephone company
will notify you in advance that temporary discontinuance of service may be required.
But if advance notice isn't practical, the telephone company will notify the
customer as soon as possible. Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations
or procedures that could affect the operation of the equipment. If this happens
the telephone company will provide advance notice in order for you to make
necessary modifications to maintain uninterrupted service.
If trouble is experienced with this FreeStyl 2, for repair or warranty information,
please contact:
Company: Senao Networks, Inc.