User's Manual

10
Copyright © 2006 Sena Technologies, Inc. All rights reserved.
2.1 Network Settings
(1) Parani-MSP™ power-up; ‘POWER’ and ‘STATUS’ LEDs display green
(2) Parani-MSP™ network configuration: connect Parani-MSP™ to PC via RS232
cable
(3) Open HyperTerminal
(4) Set PC COM port;
Baud rate 115200 / 8 Data bit / non-parity / 1 stop bit / no hardware flow control
(5) Press Enter key; the following information is displayed on HyperTerminal
screen; If Parani-MSP™ prompts Login ID/password, default values are:
Login: admin
Password: 11111
(6) Default Parani-MSP™ IP address factory setting is 192.168.1.10
. Revise to
user appropriate networking environment IP address
(7) To revise Network Settings, click main menu Number. Enter “1”
as displayed below.
(8) Network Settings sub menu is displayed.
Description:
1. Static IP: For Assigning Parani-MSP™ a static IP
2. DHCP: For Assigning Parani-MSP™ IP using DHCP
3. PPPoE: For assigning Parani-MSP™ IP using PPPoE
4. DHCP server: For instant network setting. Parani-MSP assigns temporary IP to
PC.