Data Sheet
www.self-ecg.com
Last update: 23 Feb, 2018
Page: 2 of 5
In
Input
Other
Note
Note
Ambient
and Life
Protection
Output
Model
Specifications
Specifications:
turn on time(S)
turn on time(S)
output power(W)
output power(W)
output votage(V)
output votage(V)
output voltage tolerance
output voltage tolerance
ripple voltage(mV)
ripple voltage(mV)
working current range(A)
working current range(A)
dimming interface
dimming interface
dimming range
dimming range
rated supply voltage(Vac)
rated supply voltage(Vac)
voltage range(Vac)
voltage range(Vac)
line frequency(Hz)
line frequency(Hz)
input current(mA)
input current(mA)
efficiency
efficiency
average efficiency
average efficiency
no load power consumption(W)
no load power consumption(W)
power factor
power factor
inrush current(Ipk)
inrush current(Ipk)
over voltage protection
over voltage protection
short circuit protection
short circuit protection
over temperature protection
over temperature protection
automatic restart
automatic restart
over load protection
over load protection
surge capacity
surge capacity
Ta(
Ta(℃
)
)
Tc max.(
Tc max.(℃
)
)
Storage Temperature(
Storage Temperature(℃
)
)
ambient humidity range
ambient humidity range
audible noise(dB)
audible noise(dB)
nominal life-time(hrs)
nominal life-time(hrs)
weight(g)
weight(g)
dimensions (L×W×H)(mm)
dimensions (L×W×H)(mm)
casing material
casing material
housing colour
housing colour
type of protection
type of protection
protection class
protection class
500
262×40×23
Metal
Silver
IP67
Class I
1. Tolerance:includes set up tolerance, line regulation and load regulation.
2. Tested at full load,230Vac(Input current tested at full load,120Vac).Refer to"Power Factor" and "EFFICIENT"curve graphs.
3. Calculate the model’s average efficiency for each test voltage by testing at 100%, 75%, 50%, and 25% of
rated current and then computing the simple arithmetic erage of these four values.
4. All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of
ambient temperature.
5. The power supply is considered as a component that will be operated in combination with final equipment.
Since EMC performance will be affected by the complete installation, the final equipment manufacturers must
re-qualify EMC Directive on the complete installation again."
320Vac,1 hours.
Yes
Yes
Yes
Yes
L-N: 2KV L,N-PE: 4KV
-40...80
5%...85%RH,Not condensing
≤25 @20cm
100'000@Tc=75℃
No
n/a
100-277
90-305
50/60
900
92.0%
88.0%
0.3
0.95
75A/200us
100-277
90-305
50/60
900
92.5%
89.0%
0.3
0.95
75A/200us
-40…60
2
2
2
1
3
≤ 0.5
96
12
+/-5%
500(Vp-p)
0-8
SLT96-12VLC-UN
SLT96-12VLC-UN
≤ 0.5
96
24
+/-5%
500(Vp-p)
0-4
SLT96-24VLC-UN
SLT96-24VLC-UN
90 85