Specifications
Specifications:
In
Input
Other
Note
Note
Ambient
and Life
Protection
Output
Model
turn on time(S)
turn on time(S)
output current(mA)
output current(mA)
output current tolerance
output current tolerance
output current regulation
output current regulation
ripple current(mA)
ripple current(mA)
working voltage range(V)
working voltage range(V)
Max. output voltage(V)
Max. output voltage(V)
dimming interface
dimming interface
dimming range
dimming range
rated supply voltage(Vac)
rated supply voltage(Vac)
voltage range(Vac)
voltage range(Vac)
line frequency(Hz)
line frequency(Hz)
input current(mA)
input current(mA)
eciency
eciency
power factor
power factor
inrush current(Ipk)
inrush current(Ipk)
over voltage protection
over voltage protection
short circuit protection
short circuit protection
over temperature protection
over temperature protection
automatic restart
automatic restart
over load protection
over load protection
surge capacity
surge capacity
Ta(
Ta(℃
)
)
Tc max. (
Tc max. (℃)
audible noise(dB)
audible noise(dB)
Storage Temperature(
Storage Temperature(℃)
ambient humidity range
ambient humidity range
nominal life-time(hrs)
nominal life-time(hrs)
weight(g)
weight(g)
dimensions (L×W×H)(mm)
dimensions (L×W×H)(mm)
casing material
casing material
housing colour
housing colour
type of protection
type of protection
protection class
protection class
2
2
1
n/a
YES
YES
YES
YES
L-N: 1KV L,N-PE: 2KV
-20--50
90
25
-30...80
5%...85%RH,Not condensing
50'000@Tc=90℃
230
280x30x22
plastic
grey
IP20
Built-in
SLT80-700IL-EU
SLT80-700IL-EU
≤0.5
+/-5%
±10%
420
No
n/a
220-240
198-264
50/60
410
325
120-246120-228120-213120-200 80-188 80-178 80-168 80-160 70-152 70-145
94.0% 93.9% 93.8% 93.6% 93.5% 93.4% 93.2% 93.0% 92.8% 92.6% 92.5% 92.5% 92.3% 92.2% 92.1% 92.0%
70-139 70-133 60-128 60-123 60-118 60-114
350 375 400 425 450 475 500 525 550 575 600 625 650 675 700
0.90C
40A/140us
≤3%
3
1.Tolerance : includes set up tolerance, line regulation and load regulation.
2.Tested at full load,230Vac.Refer to"Power Factor" and "EFFICIENT"curve graphs.
3.Output LF current ripple (< 200 Hz)
4.All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of ambient
temperature.
5.The power supply is considered as a component that will be operated in combination with final equipment. Since
EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.