Data Sheet

Last update: 16 June 2016
Page: 2 of 5
www.self-ecg.com
Specifications
Specifications
In
Input
Other
Note
Note
Ambient
and Life
Protection
Output
Model
output current tolerance
output current tolerance
ripple current(mA)
ripple current(mA)
working voltage range(V)
working voltage range(V)
Max. output voltage(V)
Max. output voltage(V)
output votage (V)
output votage (V)
output voltage tolerance
output voltage tolerance
ripple voltage(mV)
ripple voltage(mV)
working current range(A)
working current range(A)
rated supply voltage(Vac)
rated supply voltage(Vac)
voltage range(Vac)
voltage range(Vac)
line frequency(Hz)
line frequency(Hz)
input current(mA)
input current(mA)
efficiency
efficiency
power factor
power factor
inrush current(Ipk)
inrush current(Ipk)
over voltage protection
over voltage protection
short circuit protection
short circuit protection
over temperature protection
over temperature protection
automatic restart
automatic restart
over load protection
over load protection
surge capacity
surge capacity
Ta(
Ta(
)
)
Tc max.(
Tc max.(
)
)
Storage Temperature(
Storage Temperature(
)
)
ambient humidity range
ambient humidity range
nominal life-time(hrs)
nominal life-time(hrs)
weight(g)
weight(g)
dimensions (L×W×H)(mm)
dimensions (L×W×H)(mm)
casing material
casing material
housing colour
housing colour
type of protection
type of protection
protection class
protection class
39
68×35×20
Plastic
White
IP20
CLASSII
YES
YES
YES
YES
YES
L-N: 500V
220-240
198-264
50/60
90
78.6%
0.55
7A/180us
-20...+45
80
-30...80
5%...85%RHNot condensing
30'000@Tc=80
2
2
1
1
YES
YES
YES
YES
YES
L-N: 500V
SLT6-350ILs
SLT6-350ILs
SLT6-700ILs
SLT6-700ILs
1. Tolerance:includes set up tolerance, line regulation and load regulation.
2. Tested at full load,230Vac.Refer to"Power Factor" and "EFFICIENT"curve graphs.
3. All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of
ambient temperature.
4. The power supply is considered as a component that will be operated in combination with final equipment.
Since EMC performance will be affected by the complete installation, the final equipment manufacturers must
re-qualify EMC Directive on the complete installation again."
No
n/a
0.5
350
+/-8%
35(Ip-p)
7.5-21
25
24
+/-1.5%
350(Vp-p)
0-0.3
0.5
700
+/-8%
140(Ip-p)
3-9
13
12
+/-1.5%
250(Vp-p)
0-0.5
220-240
198-264
50/60
80
74.5%
0.55
7A/180us
turn on time(S)
turn on time(S)
output current(mA)
output current(mA)
dimming interface
dimming interface
dimming range
dimming range
CC
CC
CV
CV