Data Sheet
www.self-ecg.com
Last update: 10 Sep, 2014
Page: 2 of 4
Specifications
Specifications:
In
Input
Other
Note
Note
Ambient
and Life
Protection
Output
Model
turn on time(S)
turn on time(S)
output current(mA)
output current(mA)
output current tolerance
output current tolerance
ripple current(mA)
ripple current(mA)
working voltage range(V)
working voltage range(V)
Max. output voltage(V)
Max. output voltage(V)
dimming interface
dimming interface
dimming range
dimming range
rated supply voltage(Vac)
rated supply voltage(Vac)
voltage range(Vac)
voltage range(Vac)
line frequency(Hz)
line frequency(Hz)
input current(mA)
input current(mA)
efficiency
efficiency
power factor
power factor
inrush current(Ipk)
inrush current(Ipk)
over voltage protection
over voltage protection
short circuit protection
short circuit protection
over temperature protection
over temperature protection
automatic restart
automatic restart
over load protection
over load protection
surge capacity
surge capacity
Ta(
Ta(℃
)
)
Tc max. (
Tc max. (℃
)
)
Storage Temperature(
Storage Temperature(℃
)
)
ambient humidity range
ambient humidity range
nominal life-time(hrs)
nominal life-time(hrs)
weight(g)
weight(g)
dimensions (L×W×H)(mm)
dimensions (L×W×H)(mm)
casing material
casing material
housing colour
housing colour
type of protection
type of protection
protection class
protection class
42
52×30×23
Plastic
White
IP66
CLASS II(Euro Standard)+Class2 output(NA Standard)
1.Tolerance : includes set up tolerance, line regulation and load regulation.
2.Tested at 100Vac input.
3.Tested at full load.Refer to"Power Factor" and "EFFICIENT"curve graphs.
4.All parameters NOT specially mentioned are measured at nominal voltage input, rated load and 25 of ambient
temperature.
5.The power supply is considered as a component that will be operated in combination with final equipment. Since
EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.
≤0.5
350
+/-10%
55(Ip-p)
3-12
16
≤0.5
500
+/-10%
70(Ip-p)
3-9.5
13
No
n/a
3
3
1
2
SLT3-350ISC
SLT3-350ISC
SLT3-500ISC
SLT3-500ISC
SLT3-700ISC
SLT3-700ISC
YES
YES
YES
YES
YES
L-N: 500V
YES
YES
YES
YES
YES
L-N: 500V
YES
YES
YES
YES
YES
L-N: 500V
100-240
90-264
50/60
60
66.00%
0.45
30A/60us
≤0.5
700
+/-10%
100(Ip-p)
3-4.5
8
100-240
90-264
50/60
60
63.00%
0.45
30A/60us
100-240
90-264
50/60
60
49.00%
0.45
20A/80us
-20...50
85
-30...80
5%...85%,Not condensing
35'000@Tc=80℃