Data Sheet

www.self-ecg.com
Page: 2 of 5
In
Input
Other
Note
Note
Ambient
and Life
Protection
Output
Model
Specifications
Specifications
turn on time(S)
turn on time(S)
output current(mA)
output current(mA)
output current tolerance
output current tolerance
ripple current(mA)
ripple current(mA)
working voltage range(V)
working voltage range(V)
Max. output voltage(V)
Max. output voltage(V)
dimming interface
dimming interface
dimming range
dimming range
rated supply voltage(Vac)
rated supply voltage(Vac)
voltage range(Vac)
voltage range(Vac)
line frequency(Hz)
line frequency(Hz)
input current(mA)
input current(mA)
efficiency
efficiency
power factor
power factor
inrush current(Ipk)
inrush current(Ipk)
over voltage protection
over voltage protection
short circuit protection
short circuit protection
over temperature protection
over temperature protection
automatic restart
automatic restart
over load protection
over load protection
surge capacity
surge capacity
Ta(
Ta(
)
)
Tc max. (
Tc max. (
)
)
Storage Temperature(
Storage Temperature(
)
)
ambient humidity range
ambient humidity range
nominal life-time(hrs)
nominal life-time(hrs)
weight(g)
weight(g)
dimensions (L×W×H)(mm)
dimensions (L×W×H)(mm)
casing material
casing material
housing colour
housing colour
type of protection
type of protection
protection class
protection class
85.3x41x22/66.7x41x22
Plastic
Grey+Blue
IP20
CLASS II
1.Tolerance : includes set up tolerance, line regulation and load regulation.
2.Tested at full load,230Vac.Refer to"Power Factor" and "EFFICIENT"curve graphs.
3.All parameters NOT specially mentioned are measured at nominal voltage input, rated load, 25 of ambient
temperature and no dimmer.
4.The power supply is considered as a component that will be operated in combination with final equipment. Since
EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify
EMC Directive on the complete installation again.
Leading or Trailing Edge
10-100%
2
1
2
SLD15-300IB-Es
SLD15-300IB-Es
SLD15-300IL-Es
SLD15-300IL-Es
SLD15-350IB-Es
SLD15-350IB-Es
SLD15-350IL-Es
SLD15-350IL-Es
SLD15-500IB-Es
SLD15-500IB-Es
SLD15-500IL-Es
SLD15-500IL-Es
SLD15-700IB-Es
SLD15-700IB-Es
SLD15-700IL-Es
SLD15-700IL-Es
220-240
198-264
50/60
90
80.8%
0.95
2A/17.7us
220-240
198-264
50/60
90
80.3%
0.95
2A/17.7us
0.5
350
+/-5%
20
24-42
60
0.5
300
+/-5%
15
24-48
60
0.5
500
+/-5%
25
17-30
50
0.5
700
+/-5%
37
9-22
35
220-240
198-264
50/60
90
80.4%
0.95
2A/17.7us
220-240
198-264
50/60
90
78.9%
0.95
2A/17.7us
320Vac,1 hour
In case of a short circuit on the secondary side,the ECG will switche off
ECG switchs off if the temperature reaches a certain degree
ECG works in pulsed light output mode
After elimination of the fault condition the ECG will recover automatically
L-N:0.5KV
85
-30...80
5%...85%RHNot condensing
50'000@Tc=85
95
-25…50