User's Manual

Table Of Contents
Model 1150A DVOR
9-22 Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
c. Enter the Az Angle Low PreAlarm Limit that is needed, then press [F7]. Monitor No 1 and 2s new Az
Angle Low PreAlarm Limit will be entered into the station’s temporary memory.
9.7.14.2
Setting Monitor Az Angle High Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the az angle high alarm limit that is needed, then press [F7].
c. Enter the az angle high prealarm limit that is needed, then press [F7]. Monitor No. 1s new az angle low
prealarm limit will be entered into the station’s temporary memory.
9.7.14.3
Setting High Monitor 30 Hz Mod Low Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the 30 Hz Mod low alarm limit that is needed, then press [F7]. Monitor No. 1 and 2s 30 Hz Mod
low limit will be entered into the station’s temporary memory.
c. Enter the 30 Hz Mod low prealarm limit that is needed, then press [F7]. Monitor No. 1 and 2’s new 30 Hz
Mod low prealarm limit will be entered into the station’s temporary memory.
9.7.14.4
Setting Monitor 30 Hz Mod High Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the 30 Hz Mod high alarm limit that is needed, then press [F7]. Monitor No. 1 and 2s new 30 Hz
Mod high limit will be entered into the station’s temporary memory.
c. Enter the 30 Hz Mod high prealarm limit that is needed then press [F7]. Monitor No. 1 and 2’s new 30 Hz
Mod high prealarm limit will be entered into the station’s temporary memory.
9.7.14.5
Setting Monitor 9960 Hz Mod Low Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the 9960 Hz Mod low alarm limit that is needed, then press [F7]. Monitor No. 1 and 2s new 9960
Hz Mod low limit will be entered into the station’s temporary memory.
c. Enter the 9960 Hz Mod low prealarm limit that is needed, then press [F7]. Monitor No. 1 and 2s new
9960 Hz Mod low prealarm limit will be entered into the station’s temporary memory.
9.7.14.6
Setting Monitor 9960 Hz Mod High Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the 9960 Hz Mod high alarm limit that is needed, then press [F7]. Monitor No. 1 and 2s new 9960
Hz Mod high limit will be entered into the station’s temporary memory.
c. Enter the 9960 Hz Mod high prealarm limit that is needed, then press [F7]. Monitor No. 1 and 2s new
9960 Hz Mod high prealarm limit will be entered into the station’s temporary memory.
9.7.14.7
Setting Monitor 9960 Hz Dev Low Limit
a. Select Monitors>>Configuration>>Alarm Limits. The Alarm and Prealarm limits will be displayed for
Monitor 1 and Monitor 2.
b. Enter the 9960 Hz Dev low alarm limit that is needed, then press [F7]. Monitor No. 1 and 2’s new 9960 Hz
Dev low limit will be entered into the station’s temporary memory.
c. Enter the 9960 Hz Dev low prealarm limit that is needed, then press [F7]. Monitor No. 1 and 2’s new 9960
Hz Dev low prealarm limit will be entered into the station’s temporary memory.