User's Manual

Table Of Contents
Model 1150A DVOR
9-2 Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
9.5 INSTALLATION PROCEDURES
9.5.1 Tools and Test Equipment Required
Refer to Table 9-1 for a list of special tools and test equipment required. Refer to Table 9-2 for a list of tools needed
for installation but not for normal operation of the system.
Table 9-1 Tools and Test Equipment
(Equivalent tools and test equipment may be used)
Part Number Description
Dummy Load, 50 ohm, 100 Watt, Load, 1kW max.
950270-0000 Dummy Loads, 50 ohm, 5 Watt (5 required)
399006-0000 ESD Wrist Strap (part of 470643-0001 Accessory Kit)
339003-0000 SMA Torque Wrench (5/16”)
950552-0117 1 Watt Element
950552-0301 5 Watt Element
950552-0131 10 Watt Element
950552-0405 100 Watt Element, Bird, 100C
950552-0306 or
950552-0406
250 Watt Element, Bird, 250B or 250C or
Bird 250C
Table 9-2 Tools Needed for Installation
(Equivalent test equipment may be used)
Part No. Description
Theodolite
950505-0000 Vector Voltmeter, HP, Model 8508A with
Accessory Kit, Vector Voltmeter, Model HP11570A
950505-0001 Or Agilent Model 8712 Network Analyzer
234617-0000 NARDA Bi-directional Coupler, PN 3020A
Soldering Iron, 30 watt
Soldering Gun, 120 Watt
Heat Gun, Ungar, Professional Model 6970
900065-0000 Silicon Sealant
3/16" Drill Bit
2-1/2" Hole Saw
9.5.2 Counterpoise and Shelter Foundation Installation
Refer to Figure 9-1 and Figure 9-2. The counterpoise and shelter foundation drawing is a typical installation
drawing and will change per local building codes. Refer to SELEX-SI VOR Counterpoise Manual Part Number
571150-0006 for complete details about an SELEX-SI supplied VOR Counterpoise. For counterpoise and shelters
not supplied by SELEX Sistemi Integrati Inc., the manufacturer of the counterpoise or shelter should supply
drawings for the siting engineer.