User's Manual

Table Of Contents
Model 1150A DVOR
Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
3-57
3.6.8.5
Transmitter Commands
The Transmitter Commands menu is shown in Figure 3-52. These commands provide direct control of transferring
between the Main and Standby transmitters, controlling the output of Transmitter 1 or 2, or setting the between
Normal, Continuous, or No Ident output. Note that the Transmitter control commands can also be accessed using the
corresponding buttons in the PMDTs Sidebar. Selection of Hold Commutator brings up Figure 3-53. The Hold
Commutator window allows entry of the sideband antenna which the rotation stops and radiates on only the chosen
antenna position. If the antenna number is odd then Sideband 1 supplies power and all other Sidebands turned off. If
the antenna number is even then Sideband 2 supplies power with all other Sidebands turned off.
Figure 3-52 Transmitter Commands Menu
Figure 3-53 Hold Commutator Control Menu