3.6.8.1.2 Monitor Configuration Screens
The PMDT contains the following Monitor Configuration Screens that are used to configure the VORs Monitors.
These screens and their contents are described below.
3.6.8.1.2.1
General Configuration Screen
The General Configuration screen is shown in Figure 3-34. This screen is used to configure the general operation of
the VOR’s Monitors. It contains controls used to enable the Executive Alarm for various monitored parameters. The
user can select how each of the Executive parameters is classified, either as Primary Alarm or Secondary Alarm.
When the LCU’s Transfer Logic is set for Transfer on Primary/Secondary Alarm, any out of tolerance condition of a
Primary or Secondary Parameter will cause the system to be shutdown. Setting the LCUs Transfer Logic to Best
Availability” allows the LCU to keep the system operating in the event of only a Secondary Alarm.
Figure 3-34 General Monitor Configuration