User's Manual

Table Of Contents
Model 1150A DVOR
Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
3-25
Ta
ble 3-3 General Configuration Parameters
Parameter Description
Monitor/LCU Configuration
Monitor Integrity Tests Enabled Monitor Integrity test is enabled when checked.
Monitor Voting Logic
(applies to Dual
Monitor/Transmitter systems)
Selects either AND or OR voting logic for multiple monitor systems.
When OR voting logic is enabled, the additional option of reverting to
AND logic when on Standby is available. This option can be selected to
potentially lengthen a system’s on-air operational time.
Transfer Logic
Configures a dual system to transfer either on a Primary or Secondary
Alarm, or for Best Availability.
Automatic Restarts
Automatic Restarts Enabled
Both Automatic Restarts (first is adjustable and second fixed) are enabled
when the checkbox is checked, and disabled when it is not checked.
First Restart Delay (seconds)
Sets the delay following a shutdown until the system will automatically
restart. The system also has an additional 5 minute (fixed) restart delay.
RCSU Configuration
RCSU Present When checked, the connection between the RCSU and RMS is enabled.
Connection Type
Note:
After changing this parameter,
the new configuration will not
take effect until it has been
backed up (RMS >> Config
Backup), and the system reset
or power-cycled.
Set toDedicated Modem” when connecting to the RCSU via the VOR’s
embedded RCSU Modem.
Set to “RF Modem/Fiber” when connecting to the RCSU via the External
RCSU Modem port to a serial-based communication link, such as RF
Modems, or Fiber Optic converters.
DME Configuration
DME Type Enables the optional DME COM link to the specified type of equipment.
Digital I/O Configuration
Smoke Alarm
Smoke Alarm detection is enabled when checked. Optionally, the smoke
alarm can be cleared remotely via the RCSU or PMDT.
Intrusion Alarm
Intrusion Alarm detection is enabled when checked. Optionally, the
intrusion alarm can be cleared remotely via the RCSU or PMDT.
Spare #1 Usage Configures the Spare Input #1 Channel
Spare #2 Usage Configures the Spare Input #2 Channel
Spare #3 Usage Configures the Spare Input #3 Channel
Spare #4 Usage Configures the Spare Input #4 Channel
Modem Configuration
Connection Type Selects between Internal Modem or RF external modem
Dial In # Rings Sets the ring number that the VOR’s modem answers incoming calls
Dial Out on Status Change
Allows the VOR to dial out to report a change in status. Either an ASCII
text-based message or a SELEX-SI RSMS message can be sent.
Dial Out Phone Number The phone number to be used for the Dial-out on Status Change feature.
Tone Dial Out
Tone dialing is used to dial out when checked.
Pulse dialing is used to dial out when it is not checked.