User's Manual

Table Of Contents
Model 1150A DVOR
Rev. - November, 2008
This document contains proprietary information and such information may not be disclosed
to others for any purposes without written permission from SELEX Sistemi Integrati Inc.
3-3
Refer to T
able 3-1 for a list of functions available through the PMDT.
Note that throughout this manual, the nomenclature used to indicate the navigation through the PMDT application(s
menus and selections is as follows:
System >> Connect >> Navaid >>Serial/USB Using the mouse (left-click) or keyboard (highlight & press
Enter), select the System menu, then the Connect menu item,
then the Navaid menu item, then the Direct menu item.
Table 3-1 PMDT Available Functions
System
Logon RMS
Log on to the VOR
Logoff/Disconnect
Logs off from the system. Also disconnects the RMM Modem
Configuration Save
Saves the current configuration settings to a specified file
Configuration Load
Loads the configuration settings from a specified file
Configuration Print
Prints the configuration settings to the printer
PMDT Setup
General PMDT application configuration settings COM port, GUI
Language, etc.
Print Setup
Configures the printer output. Refer to the Windows XP help for printer
setup
Exit PMDT
Closes the PMDT application
RMS
Status
Selects the RMS Status Screen
Data
Selects the RMS Data Screen
Logs
Selects the RMS Logs Screen
Configuration
Selects the RMS Configuration Screen
Commands
Opens the RMS Commands Menu
Config Restore
Restore configuration settings from EEPROM
Config Backup
Backup configuration settings to EEPROM
Monitors
Data
Displays the Integral, Standby and Maintenance Data for both Monitors
Configuration
Settings for limits, delay times and Offset/Scale Factors
Commands
Opens the Monitor Commands Menu
Monitor 1 or 2
Data
Displays the Integral, Standby and Maintenance Data for both Monitors
Test Results
Selects the Test Results screen
Fault History
Selects the Fault History screen
Offsets & Scale Factors
Configures the Monitor offsets and scale factors
Test Signal Output (J3)
Determines which signal is connected to Monitor connector J3
Transmitters
Data
Selects the Transmitters Data Screen
Configuration
Selects the Transmitters Configuration Screen
Commands
Opens the Transmitter Commands Menu
Diagnostics
Power Up Results
Displays the results of the last Power-Up Diagnostic tests
Fault Isolation
Used to run Automatic Fault Isolation and display the results
Info
About PMDT
Displays PMDT Version and Date information