User's Manual
MODEL 2130 MARKER BEACON
4-2 Rev. A April, 2005
This document contains proprietary information and such information may not be disclosed to others for any
purposes without written permission from SELEX Sistemi Integrati Inc.
4.3 Other Onsite Maintenance
Table 5-2 is a list of onsite maintenance tasks, other than performance checks, that are necessary to prevent deterioration
of the equipment and ensure its reliable operation.
Table 4-2 Other Onsite Maintenance Checks
Reference Paragraph or Table
Standards and Maintenance
Maintenance Check Tolerances Procedures
Monthly
Perform Equipment time update n/a 5.2.2
Quarterly
a. Check all warning signs n/a 5.4.1
b. Check Vegetation control n/a 5.4.1
Semiannually
a. Check shelter air filters (if installed) n/a 5.4.1
b. Perform equipment time update. n/a 5.2.2
Annually
a. Clean/ Inspect all equipment n/a 5.4.1
b. Perform backup power (battery) check n/a 5.4.2
c. Measure VSWR at transmitter Table 3-1 5.3.4
d. Inspect RF cables n/a 5.4.3
As Required
a. Measure VSWR at antenna feedlines Table 3-1 5.3.7
b. Measure RF cable insulation resistance Table 3-1 5.4.4
c. Measure RF cable dc resistance Table 3-1 5.4.5