User's Manual

MODEL 2130 MARKER BEACON
2-16 Rev. A April, 2005
This document contains proprietary information and such information may not be disclosed to others for any
purposes without written permission from SELEX Sistemi Integrati Inc.
Bit 7 Reserved Reserved
Addr = 85 Write Read
Bit 0 Reserved Key Bit
Bit 1 Reserved Blink Enable Bit
Bit 2 Reserved Transfer (EPLD2)
Bit 3 Reserved Standby Shutdown/Enable Restart
Bit 4 Reserved Shutdown(EPLD2)/Log Error
Bit 5 Reserved ON 2 (EPLD2)
Bit 6 Reserved ON 1 (EPLD2)
Bit 7 Reserved Antenna Select 1 (EPLD2)
Addr = 86 Write Read
Bit 0 Reserved Combined Monitor Logic (And/Or)
Bit 1 Reserved Transmit Blanking
Bit 2 Reserved Hot Standby
Bit 3 Reserved SCON0
Bit 4 Reserved SCON1
Bit 5 Reserved SCON2
Bit 6 Reserved SCON3
Bit 7 Reserved SCON4
Addr = 87 Write Read
Bit 0 Reserved Combined Monitor Logic (And/Or)
Bit 1 Reserved 0
Bit 2 Reserved Reserved
Bit 3 Reserved Reserved
Bit 4 Reserved 0
Bit 5 Reserved 0
Bit 6 Reserved 0
Bit 7 Reserved 0
Addr = 88 Write Read
Bit 0 Reserved Reserved
Bit 1 Reserved Reserved
Bit 2 Reserved Reserved
Bit 3 Reserved Reserved
Bit 4 Reserved Reserved
Bit 5 Reserved Reserved
Bit 6 Reserved Reserved
Bit 7 SCON5 SCON5
Addr = 89 Write Read
Bit 0 Reserved Reserved
Bit 1 Reserved Reserved
Bit 2 Reserved Reserved
Bit 3 Reserved Reserved
Bit 4 Reserved Reserved