User's Manual

MODEL 2130 MARKER BEACON
1-14 Rev. A April, 2005
This document contains proprietary information and such information may not be disclosed to others for any
purposes without written permission from SELEX Sistemi Integrati Inc.
Table 1-1 Equipment Specifications Data (Cont.)
Environmental:
Temperature -50ΕC to +70ΕC (Outdoor equipment)
-10ΕC to +55ΕC (Indoor equipment)
Relative Humidity 0 to 95%
Altitude 0 to 15,000 feet (4572 m)
Duty Cycle Continuous, unattended
Primary Power 90-264 VA C, 47 to 63 Hz, Single Phase
12 VDC +15% (built-in charger)
Power Consumption 280 VA (Max)
75 Wdc
Monitored Parameters -3 dB RF level (Adjustable)
Low % modulation (Adjustable)
External RF level (Adjustable)
Loss of keying, continuous tone
VSWR
Carrier Output Power Stability Rated Power ±0.5 dB
Modulation Stability 95 ± 5 percent over the full range of service conditions.
System Shutdown Adjustable 5 to 15 seconds
Restart System
First time 50 ± 5 Seconds
Second time 15 minutes ± 30 seconds after the initial shutdown.
Built-in Test Equipment Digital Voltmeter; Digital Wattmeter; VSWR display; Primary voltage and
current; Battery-charging voltage and current; Modulation %;
Temperature;
Battery-Charging Current 2 A (nominal)
Battery-Charging Voltage 13.7 VDC