User's Manual
Table 1-5 DME Channel Frequency Allocation
ILS/VOR Frequency Monitor Interrogator Transmitter Reply Receiver LO
DME
Channel
LOC
(MHz)
GS
(MHz)
VOR
(MHz)
Freq
(MHz)
Pulse Code
µs
Freq
(MHz)
Pulse Code
µs
Freq
(MHz)
126X - - 117.9 1150 12 1213 12 1025
126Y - - 117.95 1150 36 1087 30 1025
1.7.6 System Checkout
a. Bypass the Integral monitor and select Tx1 Main.
b. For dual equipment bypass the Standby monitor and select Tx2 Load.
c. If the DME station has an alarm condition, then refer to section Error! Reference source not found.
to perform fault isolation and corrective maintenance.
d. Perform section Error! Reference source not found. Error! Reference source not found.
procedure.
e. Perform section Error! Reference source not found. Error! Reference source not found.
procedure.
f. Perform section Error! Reference source not found. Error! Reference source not found.
procedure.
g. Perform the SELEX-SI Site Acceptance Test (SAT) Procedure for the 2160/2170 DME system. Note
if this procedure is not available then perform all remaining performance checks in section Error!
Reference source not found. of this manual.
h. Save the final DME configuration to disk using the System >> Configuration Save command from the
PMDT. It is recommended that a backup copy of the station configuration also be maintained off site.
1.7.7Performance Tuning During Flight Inspection
a. If the DME is not able to achieve usable distance then refer to section Error! Reference source not
found. Error! Reference source not found. to adjust the receiver threshold.
b. If flight inspection reports an unlock condition or a range error while on a radial approach then refer to
section Error! Reference source not found. Error! Reference source not found. to configure echo
suppression.
c. If changes to the station are made during flight inspection then create a new station configuration file
using the System >> Configuration Save command from the PMDT.