Technical data

SP PRO Specs
SP PRO INVERTER MODEL
HEB8')% HEB8')& HEB8)-& HEB8)-' HEB8&'%& SPLC1202
Continuous Power and Charge Current
at nominal DC & AC voltage @ 25 ˚C
3 kW / 125 A 4.5 kW / 188 A 5 kW / 104 A 7.5 kW / 156 A 7.5 kW / 63 A 20 kW / 167 A
Continuous Ratings at 25 ˚C
kW A kW A kW A kW A kW A kW A
3 125 4.5 188 5 104 7.5 156 7.5 63 20 167
Short Term Ratings @ 25 ˚C
30 seconds 7.5kW 10.5kW 12kW 18kW 18kW 44 kW
1 minute 5.4kW 7.6kW 8.7kW 13kW 13kW 30 kW
30 minute
60 minutes 3.2 kW 4.7 kW 5.3kW 8kW 8kW 24 kW
Nominal battery voltage 24 V 24 V 48 V 48 V 120 V 120 V
DC input voltage range (V d.c.) 20 - 34 20 - 34 40 - 68 40 - 68 100 - 170 100 - 170
DC consumption: idle 8 W
Peak Efficiency – all modes 95% 95% 96% 96% 97% 97.2%
20% load 93% 93% 94% 94% 95% 96.8%
30% load
95% 95% 96% 96% 97% 97.2%
50% load 94% 95% 95% 96% 96% 97.1%
100% load 90% 91% 93% 93% 94% 95.5%
EU efficiency
92% 92% 93% 92.5% 93% 95.6%z
(average 5, 10, 20, 30, 50 &100%)
AC OUTPUT standalone
Setting range and accuracy 210 to 240 V+/- 0.5%
Regulation
(related to 40 ˚C ratings)
<2.25% droop @ 0-100% (load power) <0.2% @ 100%
<3.5% @150%, <5% @ 200% (load power) <1.0% @ 150%
<10% @ 300% (load rating) <1.5% @ 200%
THD <3% @ 0-200% rated load
Frequency 50 or 60 Hz +/-0.005% standalone
AC SOURCE
Nominal voltage 210 to 240 V a.c.
Tolerance on nominal voltage programmable: - 1% to -15%; + 1 to +10%
Nominal input frequency 50/60Hz
Tolerance on nominal frequency programmable +/- 1% to 10%
Generator can be started by: battery SoC, DC voltage, battery load, unit temperature, time & remote control
TRANSFER CONTACTOR
AC transfer current capacity (internal) 63 A 125 A
AC transfer current capacity (external) Control provided for an external higher rated contactor
BVm68^cejihdjgXZ!\ZcZgVidgL 15 kW 30 kW
BVmidiVadjiejiidAdVY!
AC source + inverter
15 kW 30 kW
AC transfer time “no-break” (< 1/2 cycle)
Disconnect time if grid (source) fails <= 30 ms
DC Circuit Breakers - 2 pole 250A
Operating Temperature Range -10 ˚C to 60 ˚C
Storage Temperature Range -25 ˚C to 70 ˚C
BVm<g^Y;ZZYXVeVX^in rated output
Battery temperature sensor Yes
B^Yed^ciWViiZgnkdaiV\ZhZch^c\ Yes
Inverter display
22 x LEDs with auto adjusting intensity
display indicates, charger status, useable battery capacity remaining
alarms, AC status
AC status LEDs powered from AC voltage
generator control button
output mode button
alarm silence button
Digital Inputs 4 off, 12V to 60V True, < 3V False
Shunt Inputs Two user definable: Sutable for current shunts rated at 25mV - 100mV and 25 A - 500 A
Analogue Inputs 2 general purpose logged 0-60V No
Relay Outputs 4 off: 60 V, 500 mA
Digital outputs 3 off: 60 V, 5 mA
Communication port 1 USB (slave) or RS232 or 3-phase sync (adjustable baud rate of up to 57,600)
Communication port 2 RS485 or RS232 (adjustable baud rate of up to 57600)
AC Coupling with control of KACO inverters via RS485
ELBbdYjaVi^dc[gZfjZcXn 20 kHz
BZbdgngZiZci^dcd[hZii^c\h permanent
BZbdgngZiZci^dcd[ad\\ZYYViV permanent
SP LINK configuration and monitoring software standard
Dimensions h x w x d (mm)
(d = front to mounting surface)
690 x 375 x 220 870 x 540 x 290
BVhhjceVX`ZYl^i]lVaabdjci 35 kg 39 kg 40 kg 42 kg 42 kg 115 kg
STANDARDS
Safety (UPS) IEC 62040-1-1:2002 / AS 62040-1-1:2003 with CB certificates
:B89dbZhi^Xa^b^ih EN 61000.6.3:2007 No
:B8>cYjhig^Vaa^b^ih - EN 61000.6.4:2007
Grid Connect AS4777
Ctick Yes
Protection IP43
Warranty *"-nZVghXdjcignYZeZcYZci
l]Zc^chiVaaZYWnVHZaZXigdc^X6XXgZY^iZY>chiVaaZg
20