Specifications

LD600-12 Manual Selectronic Australia
7
Operation
Five LEDs are provided on the front panel to indicate a number of
parameters, and allow adjustment of some of these parameters.
LED (5) tells you what LED (1) (4) is displaying as indicated on the front
panel of the LD600-12. Pressing Mode Button (7) will change the
information being displayed.
STATUS indicators LED (5) (green) flashing
When power is first applied LED (1) should flash.
When LED (5) (green) is OFF, this indicates the LED (1) (4) is showing
the inverters STATUS, as per written notation to the right of the LEDs. In
this mode there are no adjustments to be made.
LED (1) Flashing indicated the LD600-12 is in Demand Start mode, this
indicates that no power is being drawn from the inverter so it has gone to
SLEEP to save power.
LED (1) Stays ON, the inverter has been commanded to provide power to
the load (e.g. a light switch has been turned on) so it has gone from SLEEP
mode to ON. Once the load has been removed (e.g. the light switch is turned
off) the inverter will wait 10 seconds and return to SLEEP mode.
It is good practice to have your LD600-12 in SLEEP mode as often
as possible. When the LD600-12 is in SLEEP mode it uses 0.06
amps from the battery, when the inverter is in the ON mode it uses
at least 0.50 amps from the battery.
The amount of power required to go from SLEEP to ON is adjustable and is
described on page 9.