Specifications

LD600-12 Manual Selectronic Australia
10
Low Volts Adjust LED (5) (green) FLASHING
To avoid total discharging of your battery the LD600-12 shuts down at a pre-
set low voltage. As all batteries are different, so too is the minimum voltage
they should be discharged to. The LD600-12 will leave the factory with a
setting of 11.0 volts, change this setting if required.
Hold the Mode button (7) down until LED (5) is FLASHING,
(approximately 2 seconds) indicating you are ready to adjust this setting.
Now press the Mode button (7) until the desired value is sought. LEDs (1)
(4) will return to Status after 20 seconds.
Low Volts
Cut-out
LED 1
LED 2
LED 3
LED 4
10.0 Volts
10.1 Volts
10.2 Volts
10.3 Volts
10.4 Volts
Slow Flash
Medium Flash
Fast Flash
Fastest Flash
ON
ON
ON
ON
ON
10.5 Volts
10.6 Volts
10.7 Volts
10.8 Volts
10.9 Volts
Slow Flash
Medium Flash
Fast Flash
Fastest Flash
ON
ON
ON
ON
ON
11.0 Volts
11.1 Volts
11.2 Volts
11.3 Volts
11.4 Volts
Slow Flash
Medium Flash
Fast Flash
Fastest Flash
ON
ON
ON
ON
ON
11.5 Volts
ON
After “11.5 Volts”, the next button press “rolls back” the Low DC Volts
Cut-out setting to “10.0 Volts”