Datasheet

ESG 7.23
Prescriptions and standards
Mechanical data
Housings in self-extinguishing plastic material. Protection mode IP 40
Fixing on profile rail TS 35 according to EN 60715
Connection mark according to IEC 60067-1-18a
Environmental conditions
Admissible environmental temperatures from -25 ºC ... +55 ºC (according to IEC 60068-1)
Storage and transport temperature from -25 ºC ... +70 ºC
Relative humidity 15% to 85% (according to IEC 60721-3-3 class 3K3)
Pollution degree 2, if built-in 3 (according to IEC 60664-1)
Vibration resistance 10 to 55 Hz 0,35 mm (accordingto IEC 60068-2-6)
Shock resistance 15 g 11 ms (according to IEC 60068-2-27)
Output relay
Electrical lifetime: 2 x 10
5
switching cycles at 1000 VA ohmic load
Mechanical lifetime: 20 x 10
6
switching cycles
Contact material AgNi 0,15
Supply voltage
Frequency range 48 ... 63 Hz
Duty cycle 100%, according to IEC class 1c
Protection
Protection of the unit 5 A fast
Terminals
Contact protection according VDE 0106 and VBG 4
Terminal arrangement and connecting mark according DIN 46 199
Terminal type: Terminal connection according to VBG 4 (PZ1 required) IP 20
Terminal variants: 1 wire 0,5 mm
2
... 2,5 mm
2
with/without wire end covers
1 wire 4 mm
2
without wire end covers
2 wires 0,5 mm
2
... 1,5 mm
2
with/without wire end covers
2 wires 2,5 mm
2
flexible without wire end covers
max. screw in torque: 1,0 Nm
Insulation
Overvoltage category III (according to IEC 60664-1)
Rating surge voltage: 4 kV
Electromagnetic compatibility
Electrostatic discharge: 6 kV contact, 8 kV air (according to IEC 61000-4-2)
High frequency electromagnetic fields: Level 3, 10 V/m (according to IEC 61000-4-3)
Fast transients: 4 kV / 5 kHz, 5/50 ns (according to IEC 61000-4-4)
Lightning discharge: 2 kV com., 1 kV dif., (according toIEC 61000-4-5
Cable running disturbances inducted by HF fields: Level 3, 10 V RMS (according to IEC 71000-4-6)
Spurious radiation net and aerial network: Class B (according to EN 55011)
Prescriptions
Air and leakage paces: EN 61812-1 (see Insulation)
Test voltage: EN 61812-1 (see Insulation)
Low voltage directions according to EN 61812-1 (see Insulation)
EMC emissions: IEC 61000-6-4
EMC interference stability: IEC 61000-6-2
Burst: 4 kV / 5 kHz, 5/50 ns (according to IEC 61000-4-4)
ESD: 6 kV contact, 8 kV air (according to IEC 61000-4-2)
Production standard: according to ISO 9001
Basic standards: IEC 61000-6-4, IEC 61000-4-2