Operator`s manual

5
Operation
Starting the Generator
Remover all load from the AC power point and
switch power switch to the OFF position.
Turn the engine ON/OFF switch ON. Slide the fuel
valve lever to the “on” position and close the choke
lever. Do not use the choke if the engine is warm
or the air temperature is high.
Pull the starter grip gently until resistance is felt,
then pull it briskly and the engine should start.
Return the starter grip gently, do not allow it to
snap back or the starter may be damaged. If the
engine does not start repeat the process.
Open the choke fully when the engine is warm and
running smoothly.
Stopping the Engine
To stop the engine under normal circumstances,
switch AC breaker to off position, close the fuel
valve and turn the ignition switch off. In an
emergency the engine can be quickly stopped by
simply turning the ignition switch off.
AC Application
Start engine, ensure AC breaker switch is in the
OFF position and the appliance to be connected is
turned off.
Connect appliance, and switch AC breaker switch
to the ON position.
Now appliance is ready to use.
Control Panel
Starter Handle
ENGINE CONTROLS
Fuel Tap
Choke
Lever
AC
Breaker
Switch
AC Power Point
Voltage Meter
Earth Terminal
Main Power
ON/OFF Switch
Circuit Breaker