Operator`s manual
86 OBD  
SNAPSHOT SAVE 
After completion of the data capture, the snapshot can be saved for later review. 
Press y to save this data set or n to continue without saving the data. The current 
snapshot can be reviewed immediately even if not saved. 
ACTIVE KEYS 
y Save snapshot data. 
n  Continue to Data Display phase without saving snapshot data. 
DATA DISPLAY PHASE 
At the completion of the data capture phase, <Sample> and a time stamp are displayed at 
the bottom of the screen. The trigger point is indicated by "Sample 0.0 sec". All data 
samples have a time stamp relative to the trigger. For a 50% trigger and 30-second data 
capture, the Tester displays samples from -15.0 seconds to 15.0 seconds. 
Data captured in the <SNAPSHOT> mode can be displayed in all of the formats that are 
available in the <DATA LIST> mode, except for Strip Chart. 
ACTIVE KEYS 
l r  Sequence through the sample displayed. 
u d Move the display up or down one parameter. 
Au   Move the display one page. (<DATA LIST> mode only.) 
Ad  
y Change the highlighted parameter to the next parameter in the list. (<LED/
LIST>, <BAR GRAPH>, <LINE GRAPH>, and <CUSTOM LIST> 
modes only.) 
n Change the highlighted parameter to the previous parameter in the list. 
(<LED/LIST>, <BAR GRAPH>, <LINE GRAPH>, and <CUSTOM 
LIST> modes only.) 
AY Change to the next parameter not currently displayed. (<LED/LIST>, 
<BAR GRAPH>, <CUSTOM LIST>, and <LINE GRAPH> modes only.) 
AN  Change to the previous parameter not currently displayed. <LED/LIST>, 
<BAR GRAPH>, <CUSTOM LIST>, and <LINE GRAPH> modes only.) 
! Go to <DATA LIST> mode. 
@  Go to <LED/LIST> mode. 
#  Go to <BAR GRAPH> mode. 
$  Go to <LINE GRAPH> mode. 
%  Go to <CUSTOM LIST> mode. 
( Change between large and compressed character size. 
) Turn cursor on and off. 
Ae Change ECU. 
Ah Display parameter information. 
s Print data list. 