User guide
1640 Icon LCD Keypad 9
3.5 Stay Arming
This method allows you to remain in the protected area while 
partially arming the system. Stay Zones are zones that are 
bypassed when Stay Arming. For example, when you go to 
sleep at night, doors and windows can be armed without 
arming other zones like motion detectors.
Stay Arming can also be activated using Auto-Arming 
(see page 14), a Keyswitch (see page 14) or One-Touch 
Arming (see page 12). 
3.6 Instant Arming
Instant Arming is similar to Stay Arming. Instant Arming 
partially arms your system and enables you to remain in the 
perimeter after the system is armed. However, Instant Arming 
ignores any Entry or Exit Delays Therefore, any armed zone 
that is breached will immediately generate an alarm. 
How Do I Stay Arm?
1. Close all zones in the desired area (except Stay Zones).
2. Press the   key.
3. Enter your [ACCESS CODE].
4. If required, press the key corresponding to the desired 
area, [1] or [2]. For both areas, press the other key after 
the confirmation beep. 
1640-EU03.fm Page 9 Thursday, October 5, 2006 3:50 PM