Operating instructions

-90-
Barcode unit / V • barcode unit / H
If you install a barcode unit in the device, barcodes on paper can be read.
Barcode unit speci cations
Barcode unit / V (vertical feeding)
Reading direction Vertical feeding (bars are parallel to sheet feeding direction)
Codes JAN/EAN/UPC (module 0.33 mm,0.8 times~ 2 times)
NW-7
CODE-39
CODE-128
ITF
Industrial 2 of 5
COOP 2 of 5
* The unit can be set to read up to four kinds of codes.
Reading area Sheet feeding direction: 10mm from the front edge of a sheet to 10mm
from the rear edge of a sheet
Paper width direction: ±30mm of 50-200mm from standard paper feeding edge.
Number of digits to be read Maximum 32 digits (total number of digits to be read is 150 or less)
(For CODE-128, a maximum of 64 digits if the starting character is CODE-C)
Number of labels to be read Maximum 10 (1 sheet)
Label interval 15mm or more
Barcode printing speci cations
• Length 60mm or less X height 10mm or more
(For narrow bars with widths of 0.19mm or less,
use coated labels less than 40mm long
1)
*
Barcode length requires a quiet zone (margin) more than 2.54mm on both
sides or 10 times the width of the narrow bar, whichever is bigger.
• PCS: 0.7 or more (light-source wavelength: 633nm)
• Bar width (narrow bar) 0.125-1mm
* Bar:space ratio = 1:0.85-1.15
* Recommended N:W ratio = 1:2.5
* There should not be any bleeding, chipping, blank areas, etc.
• Skew: ±5 degrees or less from the standard paper feeding edge.
* If narrow bar width is 0.19mm or less, ±2 degrees or less.
Reading side Read the top surface of a sheet as it is fed
Directions to adjust reading positions
Paper width direction: manually adjust the head position
Sheet feeding direction:
“Specifying reading start position mode”
Use command to specify reading starting position from
the front edge of a sheet and reading width for number
of barcodes.
“Whole area reading mode”
Entire area of a sheet can be read.
(Barcodes in all areas of the sheet-feeding direction
can be read.)
1
entire thickness of label sticking section is 0.25mm or less
Label must not be oated and come off.
Barcode unit / V • barcode unit / H
Barcode unit speci cations
SR-3565(E).indd 90SR-3565(E).indd 90 2007-8-16 10:21:062007-8-16 10:21:06