Operating instructions

-46-
Setting paper weight
Set detection sensitivity In the same paper weight as seat of use to detect double-feeding errors.
Paper weight can be set according to the following ve types: “Automatic,” “84g/m
2
,” “105g/
m
2
,” “128g/m
2
,” and “157g/m
2
.”
If it’s set to “Automatic,” the device detects double-feeding errors based on the weight of rst
sheet read after the device is activated.
Also, in case it is set to “Automatic”, if the count is set to “0”, all the information of the paper
weight is cleared, and the device detects the double-feeding error based on the paper weight
after the device reads the rst sheet.
1.
Press the
MENU
switch to enter the menu mode.
2.
Use the
UP
and
DOWN
switches to select the following parameters,
and press the
FEED/ENTER
switch.
3.
Use the
UP
and
DOWN
switches to select [Paper Weight] setting,
and press the
FEED/ENTER
switch.
(“
” mark ashes in the rst column of the rst line on the LCD.)
4.
Use the
UP
and
DOWN
switches to set the value.
5.
Press the
FEED/ENTER
switch to save the setting value into memory.
(The ashing
” mark disappears from the LCD.)
6.
Keep pressing the
CLEAR/EXIT
switch until it returns to normal mode,
or press the
MENU
switch to return to normal mode.
Paper weight
setting values
• Automatic
• 84g/m
2
• 105g/m
2
• 128g/m
2
• 157g/m
2
Note)
If it is set to “Automatic”, paper weight is detected based on the weight
of the rst reading sheet so that it is required to con rm if the double-
feeding error, etc., does not occur.
Data reading settings
Setting paper weight
SR-3565(E).indd 46SR-3565(E).indd 46 2007-8-16 10:19:452007-8-16 10:19:45