Product specifications
SR-1800
19
4
DIP Switch SW2 Settings
CAUTION
· Be careful when configuring settings. Marks will be misread if the settings are incorrect.
· Make sure the power is off when configuring settings.
: Indicates the factory settings.
Contents of setting SW2
No. of lines Timing type
1 2 3 4 5 6 7 8
12 lines
Control type ON ON ON OFF
Direct-under type OFF OFF OFF ON
Mark-to-mark type OFF OFF ON ON
24 lines
Control type OFF OFF ON OFF
Direct-under type ON OFF ON OFF
Mark-to-mark type ON ON OFF OFF
32 lines
Control type OFF ON OFF OFF
Direct-under type ON ON OFF ON
Mark-to-mark type OFF ON OFF ON
38 lines
Control type OFF ON ON ON
Direct-under type ON ON ON ON
40 lines
Control type OFF OFF OFF OFF
Mark-to-mark type ON OFF OFF OFF
Direct-under type ON OFF OFF ON
48 lines Direct-under type ON OFF ON ON
Automatic sheet discharge
ON ON
OFF OFF
Sheet empty detection
ON ON
OFF OFF
Timing mark error detection
ON ON
OFF OFF
(Not used)
- ON
- OFF
SW2-1 to 4: Select the number of lines to read and the timing mark type according
to the sheet used. Mark-to-mark type is set for “Without top-end margin
reading.”(Reference: “OMR Glossary” (P.45) - Timing control type, Direct under
type, Mark to mark type)
Priority is given to the settings from the computer side.