Product specifications
18
SR-1800
3
DIP Switch SW1 Settings
Configure RS-232C port communication format and other settings.
CAUTION
· Be careful when configuring settings. Communication errors will occur if settings are
incorrect.
· Make sure the power is off when configuring settings.
· DIP switch 1-6 (SW1-6) is the back side reader setting, unrelated to the RS-232C settings.
It is set to ON for double-sided specification. Meanwhile, it is set to OFF for single-sided
specification.
: Indicates the factory settings.
No. Contents of setting ON/OFF Explanation
1 Character bit length
ON 8
OFF 7
2 Parity
ON Absent (Non )
OFF Present (Valid)
3 Parity
ON Odd
OFF Even.
4 Stop bit length
ON 1
OFF 2
5
Code acceptance status
ON All codes are accepted.
OFF (See Note. 1)
6 Back side reading
ON For double-sided specification
OFF For single-sided specification
7 Flow control
ON Enabled
OFF Disabled
8 Flow control
ON RS/CS
OFF Xon-Xoff
Note 1: According to the setting of “Code Acceptance Status,” it is possible to ignore the
ASCII codes below when processing commands and data received by the device.
Depending on the computers that are connected and programs used, it may be
necessary to configure this setting.
Codes ignored: 20H, 0AH, 7FH, 1AH
NO.
OFF
ON
NO.
OFF
ON