Operating instructions
2.  Set the film speed (ISO) and shutter speed (T) 
as shown in the paragraph for "Preparing the 
Meter for Operation". 
3.  Press the measuring switch. The 
  bol on the display starts flashing. 
sym- 
4.  While the symbol is flashing (for about 90 sec.), 
fire the flash unit by pressing its test button (Fig. 
7). 
5.  The appropriate F-stop value will be displayed on 
the meter. The measured value is indicated in a 
dual display by F-stop number with bar symbols 
and bar-dot symbol marks (Fig. 8). 
6. It the 
symbol is not flashing, the 
meter cannot accept wireless flash measurement. 
Press the measuring switch again to make the 
meter ready for measurement. 
Note: 
(1)  If the measuring range is exceeded, 
  the digital F-stop number is replaced 
with either mark of E.u. (and 
for 
underexposure) or E.o. (and  for 
overexposure) (Fig. 9). 
(2) The display will continue to indicate the 
measured value for about 5 minutes after 
measurement. After this period of time the 
auto-off circuit will operate and turn the 
display off. 