Datasheet
5
Contrast Function
Setting up lighting ratios or checking the evenness of a background
or scene is push-button simple. Take a reading of the key or reference
light and press the AVE/ΔEV button to create a standard. Then press
the measuring button to display the brightness difference between the
standard and new reading.
Additional Features
Reflected light metering: Included Lumigrid or optional 1, 5, and
10-degree viewfinder spot attachments
Swivel head
9-reading memory plus averaging
Illuminated Data panel
Dust-proof and splash-proof (JIS Standard Water Resistance Class 4)
Cine frame rates from from 2 to 360 fps
Sekonic Flash Master L-358
Normal, full reading +1.3 stops brighter than
memorized standard
MEASURING BUTTON
One press reading for Ambient
or Flash
JOG WHEEL
Click stop action for positive
secure operation
LUMISPHERE
Extend for 3-D subjects,
retract for contrast readings
ELECTO-LUMINESCENT
DATA DISPL AY
Automatically comes on
in low light
MODE BUTTON
Select modes,
recall or clear memory
DIP SWITCHES
(Under battery door) Display
full, ¹⁄₂ or ¹⁄₃ stop aperture
and shutter speeds, EV and
accumulated flash readings
AVERAGE / BRIGHTNESS
DIFFERENCE
Press after one reading
to memorize for contrast
comparison, or after two or
more readings to find average
MEMORY BUTTON
Memorize up to 9 readings for
easy comparison
DUAL ISO BUTTONS
Display readings at two ISOs,
calibrate and adjust meter
Sekonic L-358 Functions
All controls are at your finger tips. Familiar Jog Wheel operation
and large LCD readout make settings fast and easy.
1 2 3 4