User manual

29
User Manual
Fig. 4.3.1 - The BB 50/200Installation
Fix the BB 50/200 to the mounting location using the four screws (holes
diameter 4 mm), see Fig. 4.3.2.
Route the CHART PLOTTER cable to the chart plotter.
Mount the transducer according to the instructions provided with it.
Connect the POWER cable to the battery. Please be advised that the
BB 50/200 when not operating will remain in Stand-By mode.
4.3.2 Installing Optional Devices
See the External Connection diagram.
4.4 STATUS LED
There are seven different LED behaviors, representing seven different diagnostic
conditions. These are described below.
1. BOOTLOADER
LED Behavior: OFF
The BB 50/200 is running in the bootloader, or is not powered on at all.
2. STANDALONE DST, NO TRANSDUCER MODE
LED Behavior: ON, steady
The BB 50/200 is in Standalone DST (Depth, Speed, Temperature) mode,
but is not pinging because Transducer ID has not detected a trans-
ducer. This condition will occur if there is no communication with the
chart plotter, and no transducer is connected.
3. STANDALONE DST
LED Behavior: 1 long flash every 2 seconds
The BB 50/200 is in Standalone DST mode, and is pinging normally.
This condition will occur if a transducer is connected properly, but there
is no communication with the chart plotter. In Standalone DST mode,
the NMEA 0183 output produces standard NMEA Depth, Speed, and
Temperature sentences.