Specifications

17
16
English
English
GUIDELINE OF CHARGING TIME/ACCURACY
Environment/Lightsource (lux)
V157/ V158
A
(minutes)
B
(hours)
C
(hours)
Generalofces/Fluorescentlight(700)
110 25 -
30W20cm/Fluorescentlight(3000 ) 30 6 120
Cloudyweather/Sunlight(10000) 10 2 35
Fairweather/Sunlight(100000) 2 0.4 9
Expected life per charge from full
charge to stoppage
10 months
Loss/gain (monthly rate)
Less than 15 seconds when the watch is worn on your wrist at
anormaltemperaturerange(5ºCto35ºC
)
Operational temperature range -10ºCto60ºC
A: Time to charge 1 day of power
B: Time required for steady operation
C: Time required for full charge
v
The above table provides only a general
guideline.
u
The watch operates while charging electricity by converting light received on the dial to
electricalenergy.Itcannotproperlyoperateunlesstheremainingenergyissufcient.Place
orstorethewatchinalocationreceivinglightetc.,tosufcientlychargeelectricity.
•
When the watch is stopped or the second hand starts moving at 2-second intervals (for
models with a second hand), charge the watch by exposing it to light.
•
The time required for charging the watch varies depending on the calibres. Check the calibre
of your watch engraved on the back cover.
•
It is recommended that the watch be charged for as long as the charging time "B" to assure
the stable movement of the watch.