User`s guide
Table Of Contents
- Introduction
- TABLE OF CONTENTS
- Chapter 1 Getting started
- Chapter 2 Basic operations
- Plotting procedures overview
- Turning the power on and off
- Installation operations
- Online and offline
- Replacing paper rolls
- Replacing the toner
- Replacing the waste toner bottle
- Replacing the process cartridge
- Manual paper feeding (cut paper)
- Pause, continue, cancel (and additional printing)
- Web function
- Cleaning the exterior
- Using paper of new standard series
- Using paper of Chinese standard series
- Limiting rolls to be used
- Chapter 3 Menu overview
- Chapter 4 Basic Menu Operation
- Chapter 5 "SETUP" Menu
- Chapter 6 "DEVICE" menu
- Chapter 7 "PAPER" menu
- Chapter 8 "FUNCTION" menu
- Chapter 9 "PROTOCOL" menu
- Chapter 10 "RESET" menu
- Chapter 11 "SYSTEM" menu
- Chapter 12 Ethernet parameter "ETHERNET"
- Chapter 13 Terioplot
- Chapter 14 Troubleshooting
- Appendix

5-32
The joints can be specified with the parameters illustrated below:
• Any combination other than CORNER = "ROUND" and JOINT =
"ROUND" may take long time for plotting.
• Lines not jointed (which are not drawn with one stroke) are excluded.
• If the attributes of lines (line color, line width, line type) change,
treatment for joints may not be performed.
• The outermost line of the plot may not be treated for joints.
■PEN ADJUST (mm) / PEN ADJUST (in)
Allows for setting of the pen width adjust value. Plots can be produced
with a pen width larger or smaller than the pen width preset with the data
or on the panel by the adjust value in the range of the maximum pen width
16 mm (0.63 inches) and minimum width 1 dot.
This setting is performed on the third hierarchy.
<Parameter (numerical value input method)>
-0.99 - +0.99 (-0.038 to +0.038 inches) Default value = 0
ROUND
MITERED
MITERED length