User`s guide
Table Of Contents
- Introduction
- TABLE OF CONTENTS
- Chapter 1 Getting started
- Chapter 2 Basic operations
- Plotting procedures overview
- Turning the power on and off
- Installation operations
- Online and offline
- Replacing paper rolls
- Replacing the toner
- Replacing the waste toner bottle
- Replacing the process cartridge
- Manual paper feeding (cut paper)
- Pause, continue, cancel (and additional printing)
- Web function
- Cleaning the exterior
- Using paper of new standard series
- Using paper of Chinese standard series
- Limiting rolls to be used
- Chapter 3 Menu overview
- Chapter 4 Basic Menu Operation
- Chapter 5 "SETUP" Menu
- Chapter 6 "DEVICE" menu
- Chapter 7 "PAPER" menu
- Chapter 8 "FUNCTION" menu
- Chapter 9 "PROTOCOL" menu
- Chapter 10 "RESET" menu
- Chapter 11 "SYSTEM" menu
- Chapter 12 Ethernet parameter "ETHERNET"
- Chapter 13 Terioplot
- Chapter 14 Troubleshooting
- Appendix

5-26
■PLAN SIZE (HP-GL only)
Sets which command is to be enabled as a drawing size command. Sets
data to OFF if the drawing size is not properly set. This setting is
performed on the third hierarchy.
<Parameter (choice input method)> : Default value
ON (PS) Sets the PS command as the drawing size.
ON (IP) Sets the IP command as the drawing size.
ON (IW) Sets the IW command as the drawing size.
OFF Disables the drawing size command.
You need to set ON (IP) and ON (IW) only when it is clear that the IP
command or IW command is used as the drawing size, to avoid causing a
printing error. (It depends on the CAD application.)
If the PS command is available when setting ON (IP) or ON (IW), the PS
command is given priority.