Specifications
6-103
GS 'g' '2' m nl nh Maintenance Counter Transmission
Code 1DH 67H 32H m nl nh
m=0
(nh×256+nl)=20, 21, 70, 148, 149,198
Function Transmits the maintenance counter value.
Transmits the maintenance counter value. The initial value of the maintenance counter
becomes the value saved in the system area. Specifies the maintenance number as (nh×
256+nl).
nh×256+nl
Hexadecimal Decimal
Counter type
14 20 Line number of paper feed (in 100-dot line)
15 21 Number of head activation times (in 100-dot line)
46 70 Drive time of printer unit (in minutes)
94 148 Line number of paper feed (every 100-dot line)
1*
95 149 Number of head activation times (every 100-dot line)
1*
C6 198 Drive time of printer unit (in minutes)
1*
*1:The value is accumulated without being reset.
Configuration of the maintenance counter data
Hexadecimal Decimal Number of data
Data 30H to 39H 48 to 57 10 bytes