Specifications
2 - 7
(3) Motor stop signal Stop the motor drive signal within 1 ms after
detecting a home switch “OFF” (100 to 250
µ
s) signal, and input a motor stop signal of at
least 25 ms.
Fi
g
ure 2-2 Motor Drive Si
g
nal Timin
g
* See Section 2.5, Home Switch, for home switch signal.
Home switch signal
Motor drive signal
Motor stop signal
ON
100
∼
250
µ
s
OFF
1 ms max.