Heat Pump User Manual
STP-H600/H1000 Series Instruction Manual
(1) STP Control Unit Front Panel
(2) Internal Battery Connector
(3) Battery Case Screw
(4) Battery Case
(5) Battery Case Front Plate
(6) Battery Internal Connector
(7) BATTERY NG Lamp
(8) RESET Switch
(9) Battery Instruction Label
(10) Battery Case Inside Plate
(11) Flat Head Screw (M2)
・注意 ・
CAUTION
◇バッテリーは1年毎に交換してく
ださい。
◇内部バッテリーと外部バッテリー
を同時に使用しないでください。
◇
Change batteries every year
.
◇
Do not use external batteries
in combination with internal
batteries
.
次回交換日/
Next exchange date
(2)
(3)
(1)
(7)
(4)
(6)
(10)
(5)
(5)
(11)
(9)
Affix this label to the front panel.
(8)
Figure 9.1 How to Replace the Internal Battery