User Manual
75 
General Setting 4 
MS  Function 
Value 
0  1 
4-1 to 8 
Print Density Selection   
(Print Density) 
Unit: 5% 
70% to 130% 
(Default setting : 100%) 
General Setting 5 
MS  Function 
Value 
0  1 
5-1 to 8 
Thermal Paper Selection 
(Thermal Paper) 
00000000B: TF50KS-EY 
00000001B: PD160R 
00000010B: P220VBB-1 
00000011B: Alpha400-2.1 
00000100B:    KT48PF 
00000101B: P5046 
Other than those above: Prohibition 
Auto Power Off Time Setting (Lower 8 bits) 
MS  Function 
Value 
0  1 
7-1 to 8 
Auto Power Off Time Setting   
(Auto Power Off Time) Lower 8 bits 
Set in seconds 
(Total of higher 8 bits and lower 8 bits: 
  0 to 65535 seconds, 
0: Setting to 0 disables the auto power off.
) 
Auto Power Off Time Setting (Higher 8 bits) 
MS  Function 
Value 
0  1 
8-1 to 8 
Auto Power Off Time Setting   
(Auto Power Off Time) Higher 8 bits 
Set in seconds 
(Total of higher 8 bits and lower 8 bits: 
  0 to 65535 seconds, 
0: Setting to 0 disables the auto power off.
) 