12
Item Specification
Dimension 3310 (W) x 610 (D) x 870 (H) mm
Power cable length 4400 ± 100 mm
Weight 60 kg or less
Color Dark gray
Maximum media width 2600 mm
Heater type Sheath heater
Warm-up time 10 minutes or less
Media path Winding or straight output
Warm air temperatur Ambient temperature + 10 ℃ or more
Fan flow control 3 levels (H, M, L)
Timer
Off time setup timer
Range: 1 to 24 hours (unit: 1 hour)
(Error: ± 1%/h)
Acquired regulations
and standards
VCCI Class A
FCC Part 15B Class A
EN55022 Class A
CSA
CE
Power consumption 3300 W or les
Input power voltage 180 to 253 VAC
Input power frequency 50/60 Hz ± 1 Hz
Instantaneous power
failure
20 msec. or more
Inrush current 35 A or less
Grounding D class grounding (The 3rd class grounding)
Operating temperature
and humidity range
Temperature: 15 to 30 ℃
Humidity: 30 to 70%RH (no condensation)
Storage temperature
and humidity range
Temperature: 5 to 35 ℃
Humidity: 10 to 80%RH (no condensation)
Dust level Equivalent to office environments.
Ventilation
Ventilation facilities are recommended for
deodorization.
Installation space
Outlet: 5 cm or more
Inlet: 30 cm or more
5. Specification