User`s guide
4-32
Change during online printing
During online printing, the media advance value can be changed in the following
procedure.
PRINTER READY
ROLL:1625/PAPER
PRINTING
ROLL:1625/PAPER
MEDIA ADV100.00%
*
100.00%
Press key or key.
Start of data reception of print image
The data LED
blinks.
Online state (idle mode) display
- When pressing key or key during printing, the presently operating media
advance value is displayed. (Second row on the display)
- The value at the start of printing is displayed on the rst row on the display and remains
unchanged until printing is nished.
- The value is incremented or decremented by 0.01 % with
, keys.
- When the value is changed, it is reected on printing immediately.
- If any key is not operated for 3 seconds, the display returns to the original display.
- Since the changed media advance value is saved as a new value, it is reected on the
next print.
(1) Adjustment of print position in vertical directions of media
To get the good printed image quality (Normally, the adjustment
is not necessary.)
Print the adjustment pattern
[ BIDIRECTION 1/2/3] .
When replacing the media with a new media
(1) Adjustment of bi-direction position (P.4-34 Adjustment procedure of [BIDIRECTION1/2/3])
(2) Adjustment of bi-direction position ( P.4-28 [Media advance value setting] )
Reading the result of adjustment pattern print,
enter the value in [ BIDIR ADJ L ] or [ BIDIR ADJ R ].
Reading the result of adjustment pattern
print, enter the value in
[ MEDIA ADV VALUE ].
Print the adjustment pattern
[ MEDIA ADV PRINT ROUGH/DETAIL ].
Print the adjustment pattern
[ NOZZLE POS ADJ ].
(2) Adjustment of print position in the right and left directions of media
(3) Adjustment of print position in the right and left directions of media
(4)Adjust the position of the picture being printed on the media
(Only when the head (K) is replaced)
Reading the result of adjustment pattern print,
enter the value in [ NOZZLE POS VAL ].
Print the adjustment pattern
[ PH TO PH ].
Reading the result of adjustment pattern print,
enter the value in [ PH TO PH VAL ].
Print the adjustment pattern
[ ADJUST PH R/L ].
Reading the result of adjustment pattern print,
enter the value in [ PH R/L ADJ VAL ].
Print the adjustment pattern
[ LS ADJ PRINT ].
Reading the result of adjustment pattern print,
enter the value in [ LS ADJ TOP VAL] and
[ LS ADJ SIDE VAL] .