User`s guide
3-40
(15) BACK ADJUST VAL
Set the back adjust value of media. This value is
used to correct the splice of two images divided by
the auto-cleaning (PH CLEANING [DURING PRINT]
performed during printing.
#BACK ADJUST VAL
>XX:+0000PULSE
XX: Selected media number
<Parameter (numeric input)>
±2000 pulses (Unit: Approx. 3.5 μm)
(16) PH REST PERIOD
Scanning of the print head rests at every certain
print length during printing. Set this time period to
prevent nozzle-out of the print head. Normally, set
it to [0000CYCLES].
#PH REST PERIOD
>XX:0000CYCLES
XX: Selected media number
Set the number of scans for print length in [(16) PH REST PERIOD].–
<Parameter (numeric input)>
0000 to 9999 Setting [0] does not perform the scan rest.
(17) PH REST TIME
Corresponding to [(16) PH REST PERIOD], set the
scan rest time. When [0] is set for [(16) PH REST
PERIOD], this parameter is ignored. Set this rest
time to prevent nozzle-out of the print head. Set it
to [10 sec] as a rule of thumb.
#PH REST TIME
>XX:10sec
XX: Selected media number
<Parameter (numeric input)>
1 to 99 seconds
Set the rest time in [(17) PH REST TIME].–