User`s guide

3-34
(1) SELECT MEDIA
Select the media number of media to be registered
or parameter-corrected. Twenty (20) media
numbers from [01] to [20] can be selected.
#SELECT MEDIA
>XX:YYYYYY
XX: Selected media number
YYYYYY: Media name
When the printer enters MEDIA REG MENU, the currently set media number is displayed
first.
When no media is set, media number [01] is displayed.
<Parameter (choice input)>
01 to 20
(2) RENAME MEDIA
Name (register) the media number selected in
[SELECT MEDIA]. Six (6) digits of character (or code)
can be entered for the media name. For character
string of 6 digits, codes, alphanumerics and
katakana characters can be used.
#RENAME MEDIA
>XX:YYYYYY
XX: Selected media number
YYYYYY: Media name
<Parameter (Character input)>
6-digit character input (codes, alphanumerics, katakana characters, etc.) P.3-21
(3) MEDIA ADV VALUE
Set MEDIA ADVANCE VALUE. Set the advance value
so that the banding (horizontal stripes of path
splicing) is not visible.
#MEDIA ADV VALUE
>XX:YYY.YY%
XX: Selected media number
YYYYYY: Media name
<Parameter (numeric input)>
097.00 to 106.00%
Note
For MEDIA ADVANCE VALUE setting, refer to [Setting media advance correction
values]. (
P.2-38)