User Manual

15
ELECTRICAL CONNECTION
Insert the powerplug firmly into an appropriate power outlet and switch it on.
The power outlet must be correctly earthed and easily accessible.
The outlet voltage and frequency must cirrespond to the voltage indicated
on the appliance taing label.
All electrical work is to be carried out by a qualified/licenced electrician,
COMMISSIONING
The below must be performed on the Gas Cooktop by an authorised installer
before leaving;
The Gas Regulator supplied is non-adjustable, to check operation turn on
and light the Rapid Burner only.
Measure and confirm the Test point pressure is 1KPa.
FINAL CHECKS
Once commissioning is done and before leaving, the installer must check:
• Gas supply has no leaks, using soap and water solution.
Every part (knobs, trivets, burners) and the gas pipe are installed properly.
Ingnition system is working correctly with all burners, individually and all at
the same time.
As each burner is lit, it produces a well defined blue flame with no yellow
tipping.
Burner flame remains lit when rotating control knob from Maximum to
minimum flame quickly.
Check that the ignition system is functioning on all burners both individually
and combined.
INSTALLATION (Cont.)