User's Manual
7
1. LCD display: This nice blue LCD will indicate the current operation status.
2. CH-ON Key: If you press this key for a few seconds your Transmitter will
switch ON and OFF. Once you have switched the unit ON, just press this
key again slightly and you can edit various parameters such as CHANNEL,
GROUP, RF POWER LEVEL and LOCK/UNLOCK. Once you are in the LOCK
position no further operation is allowed and, in a few seconds, the display
will show the current channel selected (0 to 99). Battery level will also be
shown.
3. SELECT key: Once you are in operation mode you can access this key to
edit certain parameters. Press this key for a few seconds and the unit
will enter in the MUTE mode. (In this way, you can tell your Bass Player
what you think about the Sound Engineer without everybody knowing that!).
Press it again for a few seconds and you will unmute the unit.
4 4
Mini 4P Connector: This connector is used to connect the unit with the
clip microphones, for example, HM-38 condenser microphone or LM-10
clip microphone.
3 3
1 1
4 4
2 2
Pin 2, GND
Pin 4, for Dynamic or Condenser microphone
Charge Jack: With the rechargeable batteries put inside, use the charger
supplied in your system to recharge the batteries.
5 5
Battery Compartment: This unit may be powered from one pair dry or
rechargeable batteries, UM3 size AA 1.5V.
6 6
Pin 3, Phantom power supply for Condenser microphone
Pin 1, for guitar, bass and keyboards
3.3 MOD-16P/16LV/16HS/16G, Body Pack Transmitter
3 3
1 1
2 2
5 5
4 4
8 8
7 7
6 6
10
- RF Output Power Select
Your Transmitter can operate on three different levels of output power. These are
different form the Handheld Model and the Bodypack model.
To select the proper Output Level, please press the CH/ON key three times and
you will access the OUTPUT LEVEL Menu. Then press the SELECT key to change
the output level from PL 0 to PL 2. IN a few seconds your setting will be automatically
stored and the display will show again the operating frequency.
You don't want accidental change of frequency or other setting in the middle
of a performance, do you? Any miss-operation during a live performance can
be easily avoided thanks to the LOCK function. With the LOCK function ON no
further change of setting is allowed until the Transmitter is unlocked. To access
the LOCK menu press the CH/ON key four times and then press the SELECT
key to lock or unlock the Transmitter Settings. Your choice of setting will
automatically be saved into the Transmitter in a few seconds. The blue display
shows "lock" and "unlock" depending on the operating mode.
- LOCK Function
Fig 4: LOCK
Fig 5: UNLOCK
For the Handheld model the levels are
- PL 0, the output power is 5dBm;
- PL 1, the output power is 10dBm;
- PL 2, the output power is 15dBm;
and for the Bodypack version the levels are
- PL 0, the output power is 3dBm;
- PL 1, the output power is 5dBm;
- PL 2, the output power is 12dBm;