User manual
Appendix - Parameter List
TPG User Manual 99
Table 25: Parameter List - Web access
Table 26: Parameter List - TCP port access
Parameters Value Default Description
http_allowed
[HTTP/HTTPS]
on/off on Defines the permitted type of
connection (HTTP/HTTPS) to
the TPG Control Center.
If HTTPS is exclusively chosen
as the connection type
[http_allowed = off], the
administrative access to the
TPG Control Center is
protected via SSL/TLS.
http_pwd
[Password]
max. 64 characters
[a-z, A-Z, 0-9]
[blank] Defines the password for the
administrative access to the
TPG Control Center.
Parameters Value Default Description
protection
[Port access
control]
on/off off Enables/disables the locking
of the selected ports.
protection_test
[Test mode]
on/off on Enables/disables the test
mode.
The test mode allows you to
test the parameters set using
the access control. If the test
mode is activated, the access
protection remains active until
the TPG is rebooted.
protection_level
[Security level]
protec_tcp
protec_all
protec_t
cp
Specifies the port types to be
locked:
- TCP ports
- all ports (IP ports)
ip_filter_on_1
~
ip_filter_on_8
[IP address]
on/off off Enables/disables an
exception from the port
locking.
ip_filter_1
~
ip_filter_8
[IP address]
valid IP address [blank] Defines elements that are
excluded from port locking,
using the IP address.