User manual
Administration Methods
TPG User Manual 23
The following commands are supported:
The following applies for the instructions:
• not case-sensitive
• one or more space characters are allowed
• max. length is 128 byte
• only the ASCII format can be read
Security with TAN
You will need a TAN for updates or parameter changes on the TPG.
You will get a current TAN from the TPG via email, e.g. when
receiving a status page. Enter the TAN into the first line of the email
body. A space character must follow.
Parameter Changes
Parameter changes are integrated into the email body with the
following syntax:
<parameter> = <value>
The syntax and values can be obtained from the parameter list, see:
Ö87.
Commands Option Description
<command> get status Sends the status page of the TPG.
get parameters Sends the parameter list of the TPG.
set parameters Sends parameters to the TPG.
The syntax and values can be obtained from
the parameter list, see:
Ö87.
Parameter and value must be entered into the
email body.
update tpg Carries out an automatic update using the
software that is attached to the email.
help Sends a page containing information about the
remote maintenance.
[<comment>] Freely definable text for descriptions.