Test Report
Report Reference No.: 50337286 001
UL 1012
Clause
Requirement – Test
Result – Remark
Verdict
Page 8 of 75
7.2.1
A power unit intended to be fastened in place shall have a
means for securely mounting it in position. Bolts, screws, and
other parts used for mounting the power unit shall be
independent of those used for securing components.
N/A
7.2.2
A portable power unit intended for wall mounting shall employ a
keyhole slot or the equivalent as a mounting means.
N/A
7.2.3
A barrier or the equivalent may be used to prevent wall-
mounting screws from projecting into a compartment containing
electrical parts and reducing spacings to less than that
specified in Spacings, Section 35.
N/A
7.2.4
Mounting instructions shall be furnished with each power unit
designed for permanent mounting. If special hardware is
required, it shall be provided by the manufacturer.
N/A
7.3
Integral meters
No such meters
N/A
7.3.1
If an electrical instrument, such as a meter, forms part of the
enclosure, the face or the back of the instrument housing, or
both together, shall comply with the requirements for an
enclosure.
N/A
Exception No. 1: An electrical instrument connected in a
secondary circuit need not comply with the requirements for an
enclosure if damage or deterioration of the materials
comprising the housing does not result in a risk of fire or
electric shock.
N/A
Exception No. 2: This requirement does not apply to a meter as
described in 7.3.2.
N/A
7.3.2
A panel mounted analog meter shall comply with the Standard
for Electrical Analog Instruments - Panelboard Types, UL 1437.
N/A
Exception: An analog meter connected to an isolated circuit of
not more tha42.4 n V peak or 60 V dc need not comply if the
meter housing does not constitute part of the power unit
enclosure.
N/A
7.4
Supporting material
P
7.4.1
Material supporting terminals or used as internal electrical
insulation of an electrical instrument shall comply with
Insulating Materials, Section 24.
Insulation materials are
approved
P
Exception: This requirement does not apply to an electrical
instrument connected in a secondary circuit if damage to or
deterioration of the materials does not result in a risk of fire or
electric shock.
N/A
7.4.2
Supporting feet of a power unit that form part of the enclosure
or that are needed for ventilation shall be reliably secured in
place and the aging, physical, and flammability properties of the
material shall be investigated. A rubber or neoprene material
shall comply with the physical properties test requirements
in 65.2.1.
N/A
Exception: This requirement does not apply to a power unit
subjected to the Temperature Test, Section 42, with the
supporting means removed. See 42.9.
N/A
7.4.3
An adhesive used to attach a cover to a power unit shall be
investigated with respect to exposure to environmental
conditions, such as high and low temperatures, high and low
humidity, and the like, to determine its ability to retain the cover
in position.
N/A